Crowne Plaza Hotel - Ottawa, Ontario
The Crowne Plaza Hotel is 26 storeys in height and was constructed in the late 1960's. The lower three levels are interconnected by an atrium. The services provided include the following:

  • Site evaluation.
  • Preparation of a fire protection audit analysis complete with recommendations for upgrading.
  • Preparation of sprinkler system, standpipe system, and fire detection and alarm system design documents.
  • Negotiations with Authorities.
  • Building code consulting.
Click here for photo

Le Centre Sheraton Hotel - Montreal, Quebec
Le Centre Sheraton is a 38 storey hotel. The hotel is highlighted by a six level atrium that extends from the public areas below grade to ballrooms on level four. There are also ten levels for parking below grade. Company services included:

  • Fire safety audit and report identifying existing conditions with respect to local applicable codes and ITT Sheraton Fire Safety Requirements.
  • Preparation and implementation of a master fire safety upgrading program.
  • Negotiations with Authorities.
Click here for photo

Minot Hall - Boston, Massachusetts
Minot Hall is a 5 storey historic building housing an antique museum. The services provided include the following:

  • Development of an approach for providing sprinkler protection.
  • Preparation of detailed hydraulic calculations to confirm that the existing water supply would meet fire suppression system demands.
  • Negotiations with Authorities.

Ecole Secondaire Nepisiquit - Bathurst, New Brunswick
The Ecole Secondaire Nepisiquit is a two storey high school. Services provided include:

  • Site evaluation.
  • Preparation of sprinkler system design documents for retrofit.
  • Negotiations with Authorities.
  • Construction review services.
Click here for photo

Old Government House - Fredericton, New Brunswick
The Old Government House is a three storey historic structure containing the residence of the Lieutenant Governor, offices, and a museum. Services provided include:

  • Preparation of design documentation for sprinkler and standpipe systems.
  • Negotiations with Authorities.
  • Construction review services.
Click here for photo

Sheraton Casino - Sydney, Nova Scotia
R.J. Bartlett Engineering Ltd. was retained to represent the interest of the owners with respect to local codes and standards as well as ITT Sheraton Fire Safety Requirements. Services included:

  • Building and fire code evaluation.
  • Responding to site conditions affecting fire safety.
  • Hydraulic analysis to assist in the necessary modifications of partially installed sprinkler systems.
  • Functional testing of fire detection and alarm systems, as well as the sprinkler system.
  • Preparation of the fire safety plan and system maintenance manual.
Click here for photo

Delta Edmonton South - Edmonton, Alberta
The Delta Edmonton South was constructed in the 1970's and is 11 storeys in height. The services provided include the following:

  • Site evaluation.
  • Preparation of a fire protection audit analysis complete with recommendations and budget estimates for upgrading.
  • Review of fire protection system designs.
  • Fire protection system upgrading construction review.
  • Negotiations with Authorities.
Click here for photo

Quebec Radisson - Quebec City, Quebec
The Québec Radisson occupies the lower 13 storeys of a 31 storey building. The building was constructed in the mid 1970's. The services provided include the following:

  • Site evaluation.
  • Preparation of a fire protection audit analysis complete with recommendations and budget estimates for upgrading.
  • Preparation of sprinkler and fire alarm tender documents.
  • Negotiations with Authorities.
Click here for photo

Fairmont Hotels and Resorts, Fairmont Glitter Bay and Royal Pavilion Resorts, Barbados
The Fairmont Glitter Bay and Royal Pavilion Resorts in St. James, Barbados were constructed in various stages over the past approximately 30 years. The design basis for the construction appears to be influenced by a standard of fire safety similar to that of the United Kingdom and/or the Caribbean.

R.J. Bartlett Engineering Ltd. completed an inspection of the properties following a review of drawings and a review of some model North American Building Codes as well as the existing Barbados Building Code. The mandate of R.J. Bartlett Engineering Ltd. was to provide a fire protection engineering opinion on fire safety for occupants based on the intent of model North American Building Codes and the existing Barbados Building Code.

  • Building code consulting.
  • Fire hazard analysis.
  • Performance-based analyses.
Click here for photo

Starwood Hotels and Resorts Worldwide Inc., Sheraton Gateway Toronto
This existing upscale hotel property was converted from a major brand hotel to a Sheraton. To assist in this transfer, the R.J. Bartlett Engineering Ltd. team:

  • Due diligence.
  • Conducted a site audit of fire safety features and systems.
  • Completed an analysis with respect to applicable local code requirements and standards and guidelines applicable to Sheraton hotels.
  • Identified action items, placed in items in priority sequence and provided capital cost estimates.

Architects Four Limited, Moncton Air Terminal Building and Greater Moncton Airport Authority
The new Moncton Air Terminal Building is a new three level facility with a building area of square feet.

Services included:

  • Building code consulting.
  • Development of performance-based solutions for exiting.
  • Site inspections of construction related to fire protection.
  • Witnessing fire protection system testing.

Click here for photo

Teco - Tampa, Florida
  • Sprinkler system design
  • Investigative engineering